Linux Home
Automation
(Last updated: Sat - Sep 6, 2008)
Automation
(Last updated: Sat - Sep 6, 2008)
CPUXA Eight Character ASCII PROTOCOL
ADICON 2500 Application Software Version 2.31 or later Firmware 8.21/10 or later C-Max 1.30 or later updated 5/24/99 Learn IR +R380xxx note: while this command is still supported, it is recommended that C-Max software be used to learn IR where xxx is the IR Location to learn example, learn IR # 0 +R380000 example, learn IR # 17 +R380017 example, learn IR # 81 +R380081 Send Local IR +T000xxx where xxx is the Learned IR Location to send example, send IR # 1 +T000001 example, send IR # 10 +T000010 example, send IR # 23 +T000023 Set/Clear Relay +Cmmpp0x where mm is the Module Number 01 thru 99 where pp is the I/O Point Number 00 thru 15 where x is the Relay Status to send (0 = OFF, 1 = ON) example, turn relay 2 in module 3 ON +C030201 example, turn relay 0 in module 15 OFF +C150000 example, turn relay 5 in module 10 ON +C100501 Select Remote IR Zone +Smmpp00 where mm is the Module Number 01 thru 99 where pp is the I/O Zone Number 00 thru 15 example, select zone 2 in module 3 +S030201 example, select zone 0 in module 15 +S150000 example, select zone 5 in module 10 +S100501 Send Remote IR +K000xxx note: sends IR xxx to Module and Zone selected on above command where xxx is the Learned IR Location to send example, send IR # 1 +K000001 example, send IR # 10 +K000010 example, send IR # 23 +K000023 Change Variable Contents in CPUXA +Vnnxxxx where nn is the variable # 00 thru 31 where xxxx is the new variable contents 0 thru 9999 example, change variable 4's contents to 1 +V040001 example, change variable 18's contents to 0 +V180000 example, change variable 0's contents to 8764 +V008764 Send X10 command +Xhhkkrr where hh is the house code 0 thru 15 (A-P) where kk is the key (unit) code 0 - 15 (1-16) where rr is the number of times to repeat this code 1 thru 15 example, send B 11 once +X011001 example, send B ON once +X011801 example, send B DIM 5 times +X012005 Send Extended X10 Level Command +Ehhkkbb where hh is the house code 0 thru 15 (A-P) where kk is the key (unit) code 0 - 15 (1-16) where bb is the brightness level 0 - 63 example, set H5 to 50% brightness (32) +E070432 example, set C2 to 25% brightness (16) +E020116 example, set P14 to 75% brightness (48) +E151348 Send Extended X10 Group (Scene) Command +Ehhkkgg note: Use C-Max Software to configure modules in groups where hh is the house code 0 thru 15 (A-P) where kk is the key (unit) code 0 - 15 (1-16) where gg is the group (scene) number 0 - 63 example, set H5 to group (scene) 32 +G070432 example, set C2 to group (scene) 16 +G020116 example, set P14 to group (scene) 48 +G151348